熟女一区二区三区,99国产揄拍国产精品,成人国产亚洲精品a区天堂蜜臀,日韩AV在线一区免费超清

NEWS
Solutions to Inadequate Flow Rate of Metering Pump
Time:2019-01-22 01:41:09 Browse:2922

After the metering pump is installed, we hope to be able to run normally, which can reduce many costs, but sometimes the metering pump is running without water or insufficient flow, so what causes such a situation to occur, and how to solve this problem, the small part introduces to you.

1. Reasons and solutions of metering pump failing to discharge water:
1. The inlet and outlet valves are not opened, the inlet and outlet pipelines are blocked, and the abortion impellers are blocked. The solution is to remove the blockage.
2. Hot water pump suction pipe leaks. Tighten each sealing surface to remove air.
3. The running direction of the motor is not right, and the speed of the motor without phase is very slow. Adjust the direction of the motor and strengthen the connection of the motor.
4. The metering pump is not filled with liquid and there is air in the pump chamber. Open the top cover of the pump or the exhaust valve to exhaust the air.
5. Import and export water supply is insufficient, suction range is too high, bottom valve leaks. Inspection and adjustment of shutdown (this phenomenon is easy to occur in the use of water pipes connected to the grid and with suction range).
6. Pipeline resistance is too large, and the selection of centrifugal pump is inappropriate. Reduce pipe bends and re-select pumps.

2. Reasons for insufficient flow of metering pumps and how to solve them:
1. The inlet and outlet valves are not opened, the inlet and outlet pipelines are blocked, and the abortion impellers are blocked. The solution is to remove the blockage.
2. The impellers of pipes and runners are partially blocked, and the scale deposits and the opening of valves are insufficient. Remove obstruction and adjust valve opening.
3. Low voltage of metering pump. Voltage stabilizing
4. Impeller wear. Replace the impeller.
5. Use above rated flow rate. Adjust flow and turn off outlet valve
6. Excessive suction. Reduce the suction distance.
7. Wear of pump bearing. Replace bearings.

CONTACT
Join:All the products of our company are for the whole country to recruit agents. If you want to join in business and order, please contact us by the following ways.
13771177635Mr. Liu
13921516709Mr. Zhao
Email
sales@yuanshuflow.com
Room 201-1, Famous Creative Intelligence Park,
501 Nanhu Avenue, Liangxi District, Wuxi City

Focus on Wechat Public Number

Focus on Mobile Official Website
Copyright © 2019 Wuxi YuanShu Intelligent Fluid Technology Co., Ltd. All Rights Reserved   備案號(hào):蘇ICP備19004024號(hào)